Custom Genset Power Plant Water Cooled Diesel Generator 11KV 750Rpm
G300 Statinary Generating Sets Main Specification | ||||||||
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 | ||||
Rated power, KW | 1000 | 1250 | 1350 | 1400 | ||||
Overload , KW | 1100 | 1375 | 1485 | 1540 | ||||
Rated voltage, V | 400/415/440/3300/6300/10500/13800 | |||||||
Rated current , A | ||||||||
Frequency , Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging | |||||||
Phase | 3 | |||||||
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 | G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 | 2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator | |||||||
voltage fluctuation rate% | <0.5 | <0.5 | ||||||
Frequency fluctuation rate, % | <0.5 | <0.5 | ||||||
Stable voltage regulating rate, % | ±1.0 | ±1.0 | ||||||
Transient voltage regulating rate, % | +20, -15 | +20, -15 | ||||||
Stable Frequency fluctuation rate, % | <3 | <0.5 | ||||||
Transient frequency regulating rate, % | +12, -10 | |||||||
Stablizing time, voltage , S | <4 | |||||||
Stablizing time, frequency , S | <3 | |||||||
voltage regulating method | automatic and munual | |||||||
Frequency regulating method | manual | |||||||
starting method | compressed air | |||||||
Lubricating method | pressue lubricating | |||||||
Cooking method | water cooling | |||||||
coupling | flexible | |||||||
Overdimension, mm | 3880*2150*3180 | 8470*2360*3060 | ||||||
Weight, Kg | 30000 | 35000 | 38000 |
G300 Statinary Generating Sets Main Specification | |||||||
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 | ||||
1500 | 1600 | 1800 | 2000 | ||||
1650 | 1760 | 1980 | 2200 | ||||
400/415/440/3300/6300/10500/13800 | |||||||
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging | |||||||
3 | |||||||
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 | G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator | |||||||
<0.5 | |||||||
<0.5 | |||||||
±1.0 | |||||||
20, -15 | |||||||
<0.5 | |||||||
+20, -15 | |||||||
<5 | |||||||
<4 | |||||||
automatic and munual | |||||||
manual | |||||||
compressed air | |||||||
pressue lubricating | |||||||
water cooling | |||||||
flexible | |||||||
8470*2360*3060 | |||||||
38000 | 42560 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
GN8320 Stationary Generating Sets Main Specification | ||||||||||
Model | 2400GF | 2500GF | ||||||||
Rated power, KW | 2400 | 2500 | ||||||||
Overload , KW | 2640 | 2750 | ||||||||
Rated voltage, V | 400 | 415 | 3300 | 6300 | 10500 | 400 | 415 | 3300 | 6300 | 10500 |
Rated current , A | 4330 | 4174 | 525 | 275 | 165 | 4511 | 4348 | 547 | 172 | 286 |
Frequency , Hz | 50 | 50 | ||||||||
Power factor | 0.8 Lagging | 0.8 Lagging | ||||||||
Phase | 3 | 3 | ||||||||
Diesel engine | GN832000ZD | GN8320ZD | ||||||||
Rated power, KW | 2648 | 2795 | ||||||||
Rated rev, rpm | 750 | 750 | ||||||||
Alternator | 3 phase alternator | |||||||||
voltage fluctuation rate% | ±1.0 | |||||||||
Frequency fluctuation rate, % | +12, -10 | |||||||||
Stable voltage regulating rate, % | 3 | |||||||||
Transient voltage regulating rate, % | +12, -10 | |||||||||
Stable Frequency fluctuation rate, % | 4
| |||||||||
Transient frequency regulating rate, % | 5 | |||||||||
Stabilizing time, voltage , S | +1 | |||||||||
Stabilizing time, frequency , S | +12, -10 | |||||||||
voltage regulating method | automatic and manual | |||||||||
Frequency regulating method | manual | |||||||||
starting method | compressed air | |||||||||
Lubricating method | pressure lubricating | |||||||||
Cooking method | water cooling | |||||||||
coupling | flexible | |||||||||
Overdimension, mm | 8950*2570*6050 | |||||||||
Weight, Kg | 45000 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure
charge air coolant temperature
relative humidity
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
![]() |
Customized HFO and diesel oil Genset Power Plant Water and air Cooling Generator 0.4KV-11KV 500-1000RPM Images |